Outdoor Access Points: Deployment, Environmental, and Grounding Guidance
Overview
Power plays a big role in the performance of outdoor access points. Additionally, there are numerous elements to consider with outdoor deployments, including lightning strikes. This article outlines how to mitigate lightning and other adverse electrical events.
When using the MR58, MR62, MR66, MR72 or other outdoor Cisco Meraki access points it is important remember that environmental conditions can play a factor in operating performance. Humidity and moisture can eventually erode the electrical conductivity of internal components in the unit causing severe damage, and high temperatures can cause devices to burn out.
When deploying an outdoor wireless mesh network, there are many considerations that need to be taken into account. This KB will discuss how to physically deploy the APs, antenna capabilities, and usage of gateways and repeaters, which all need to be taken into consideration when deploying an outdoor network.
Physically Deploying and Environmental Considerations
-
Mount the APs to a sturdy anchor point to prevent theft or damage due to the weather. This can be done by bolting the mount plate to a wall/ceiling or using the metal straps to attach the plate to a pole.
-
Make sure the device stays within the listed operating temperature listed in the datasheet for the model of AP being deployed. If necessary, deploy in shade or provide ventilation if in an enclosure.
-
Ethernet cabling is limited to 100 Meters (about 328 feet)
-
The Meraki PoE Injector must be deployed indoors as it is not waterproof or ruggedized
- Make sure the AP is grounded properly to prevent static buildup and to protect against other electrical issues
-
Rated speeds are theoretical maximums under ideal circumstances. Actual throughput will vary dependent on distance, environmental conditions, number of clients, and client capabilities.
Temperature and Humidity Limitations
If running Ethernet cable and power outside to the APs, make sure that the cables used are rated for outdoor use. Also consider using conduit for the cabling.
Water can absorb RF energy very effectively. It is critical to place the AP's and Antennas in areas where they will not be covered in ice or snow.
Meraki 802.3af PoE bricks and passive PoE injector for the the OD2 are not weatherproof, they must be protected from all elements. They also have a maximum operating temperature of 104 degrees Fahrenheit that should be kept in mind.
When deploying the APs and antennas in frigid temperatures, make sure the temperatures will not fall below the recommended operating temperatures.
In high wind situations be sure to have the APs properly secured and mounted.
To avoid a build-up of static electricity which can damage the electronics, ground the APs with the included grounding strap.
Please review the data sheets for the MR58, MR62, MR66, MR72 and other APs for operating temperatures on the Meraki library.
Grounding
If the Meraki Outdoor is installed and exposed to the elements, it should be properly grounded to prevent damage to the AP, connected networking equipment, and the mounting structure. The Outdoor can suffer several types of failure in the field due to a lack of grounding.
Avoiding a Lightning strike
Antennas are magnets for static electricity in the environment. The element of an antenna and its ground structure collect energy through exposure and channel it through the access point to get rid of it. The best way to avoid damage to your antenna is to choose one that can be safety grounded to the support structure. This is primarily a concern with dish or large panel antennas. For smaller antennas, the ground of the antenna connector (the outermost exposed part of an RP-SMA or N type connector) should have a cable wiring it to ground.
In the case of the MR58, using the supplied ground wire for the metal casing will provide grounding for all the antennas. For the Meraki Outdoor and Solar, a wire with a ¼” ring connector should be run from the base of the antenna to a nearby grounding point.
Protecting the Antenna(s)
A direct strike will destroy any antenna. The best chance of avoiding damage to an antenna from a lightning strike is to prevent a strike from occurring. Structures can be equipped with structural "lightning-rods" in accordance with building codes and recommendations for the area.
Protecting the Access Point
The best way to protect the AP itself from direct strike is to avoid a strike. However, in the event of a strike, some protection for the hardware can be achieved through the use of a surge arrestor. A lightning surge arrestor installs on the base of the antenna, between the antenna and the RF connector on the AP housing. It contains a fuse device (generally a fast acting gas discharge fuse) that triggers during a strike and channels the energy to a local grounding point. Surge arrestors have a small amount of signal loss, but are a worthwhile investment for access points installed in hard to reach areas or high up and likely to attract strikes.
Protecting the Structure
The ground structure for the access point, the antennas, and the cables should all be built in accordance with building codes. On any given mounting structure, a protection system typically includes a rooftop network of conductors, multiple paths to the ground, connections to the metallic portion of the structure and a grounding network.
Protecting the interior network and electronics
In the event of a strike that damages or destroys the access point installed outside, it is important to isolate and protect any equipment inside. Excess energy on the access point that can’t find it’s way to local earth ground will transfer to the interior equipment over the communication and power cable. A surge arrestor designed for use with Cat-5/6 cable should be used to prevent damage to equipment that is not directly exposed to the elements.
Static Buildup
Static buildup can cause slow and irreversible damage to the access point. This may present itself as a reduction in Transmit Power and Receive sensitivity over time, or may show as a sudden death of Ethernet communication on the active port(s). Excess static in the environment builds up on the antenna element or system ground, damaging the sensitive components when the concentration is high.
Static is especially noticeable when conditions are suitable for thunderstorms. Warm, dry, and windy conditions dramatically increase the failure rate of unprotected equipment. Damage from static buildup can be prevented with proper grounding. It is suggested to install a grounding strap from the antenna ground to a well designed local earth ground. A grounding strap can be made from a ring lug terminal (1/4” thin metal ring) and a medium length stranded copper wire (no more than 5 meters, suggested gauge AWG 14 or lower). It can be connected to the RPSMA connector on a outdoor below the antenna. (There is 1-2mm of space below the bottom of the antenna and above the enclosure nut). The other end of the wire should be firmly attached to a grounding structure.
Surges from the LAN
A shielded CAT 5 Ethernet cable connected to a third-party PoE with surge protection only protects the unit from power surges originating on the Ethernet cable or wired uplink device (e.g. your switch).
Antenna Capabilities and Requirements for Outdoor Deployments
-
Line of sight between AP’s antennas is necessary to maximize signal strength. Particularly when using sector/panel antennas.
-
Omni Antennas provide the least range, but provide near total coverage around the AP. They are best used for servicing clients or if you have a single gateway servicing multiple repeaters.
-
Sector Antennas have both a 2.4Ghz and 5Ghz versions. These increase range and limit the radio signal coverage to a smaller area. These are great for connecting repeaters to a single gateway over a longer distance or providing WiFi coverage to a focused area.
-
Environmental factors, like moisture and wind affect performance and link quality.
-
2.4Ghz band is able to travel longer distances as well as penetrate objects better.
-
5Ghz band has a higher throughput as well as more channels, so interference is less of an issue. However, this comes at a cost of range.
Usage of Gateways and Repeaters
-
Our devices automatically try to mesh as a repeater if they cannot access a gateway via their wired interface
-
One Gateway can support multiple Repeaters. However, if the single Gateway device goes down, the entire network goes down.
-
Multiple Gateways will help with redundancy as well as increase performance because repeaters must mesh on the same channel the Gateway is on. If too many AP’s and clients are on the same channel (2.4 or 5 Ghz) the link quality will degrade due to interference and channel utilization.
-
Although Repeaters can connect to other Repeaters to get to a Gateway, this is not recommended because your throughput is halved each “hop” or Repeater the far device goes through.
- A repeater will mesh to the gateway it sees as the strongest neighbor (strength of the connection). You can use client survey tools as well as wifi stumblers to map out each Gateway’s reach