Cloud Managed EVPN Fabric Technical Guide
Cisco Cloud-Managed Fabric provides a cloud-first campus architecture built on standards-based BGP EVPN and VXLAN. Meraki Dashboard centralizes Fabric definition, deployment, monitoring, and operations while preserving standards-based control-plane and data-plane behavior. This guide explains the architecture, supported platforms, segmentation models, wireless integration, automated Underlay workflows, deployment phases, assurance, and troubleshooting practices.
Why Campus Networks Are Moving Toward Fabrics
Traditional two-tier and three-tier campus architectures remain valid for many deployments. Their limitations become more apparent when organizations require extensive segmentation, active use of redundant links, deterministic convergence, endpoint mobility, and consistent services across multiple buildings, distribution blocks, or campuses.
A fabric architecture addresses these requirements by using a routed underlay for stable IP transport and an overlay to provide logical Layer 2 and Layer 3 services. This allows the physical topology to remain stable while network services are added, removed, or extended based on business and application requirements.
What Is a Campus Fabric?
A campus fabric is a network architecture that provides consistent connectivity and network services across a shared physical infrastructure. Instead of treating the network as a collection of independently configured switches and routers, a fabric uses a common transport, control plane, and service model to connect users, devices, applications, and external networks.
- The underlay provides physical IP connectivity between fabric nodes and is typically built as a resilient Layer 3 network.
- The overlay provides logical Layer 2 and Layer 3 services over the underlay and separates service topology from physical transport topology.
VXLAN overview
VXLAN (Virtual Extensible LAN) is the foundation of modern fabric architectures. It provides scalable network virtualization by encapsulating Ethernet frames inside UDP packets for transport across a Layer 3 Underlay.
VXLAN encapsulation
VXLAN uses MAC-in-UDP encapsulation to tunnel Layer 2 frames over a Layer 3 network. The original Ethernet frame is preserved and carried with an outer Ethernet, IP, UDP, and VXLAN header.
| Identifier | Field size | Address space |
|---|---|---|
| 802.1Q VLAN ID | 12 bits | 4,096 VLANs |
| VXLAN Network Identifier (VNI) | 24 bits | Approximately 16 million segments |
- Encapsulation overhead: VXLAN adds approximately 50 bytes per frame: 14-byte outer Ethernet header, 20-byte IP header, 8-byte UDP header, and 8-byte VXLAN header.
- UDP port 4789: VXLAN uses the IANA-assigned destination port 4789.
- VXLAN tunnel endpoint (VTEP): VTEPs encapsulate and decapsulate traffic at the fabric edge.
- Layer 3 transport: The outer IP header allows the Underlay to route encapsulated traffic.
- Original frame preservation: The inner Ethernet frame remains unchanged, including its Layer 2 information.
VXLAN and BGP EVPN Overlay
VXLAN and BGP EVPN combine a standards-based data plane with a standards-based control plane.
| VXLAN data plane | BGP EVPN control plane |
|---|---|
| Standards-based UDP encapsulation | Standards-based Multiprotocol BGP (MP-BGP) |
| Transport-independent Overlay | Supports VXLAN, MPLS, and Provider Backbone Bridging (PBB) data planes |
| Layer 3 Underlay transport | Supports bridging, MAC mobility, first-hop and prefix routing, and multitenancy |
| 24-bit VNI namespace with approximately 16 million identifiers | Distributes MAC and IP reachability through a unified control plane |
Fabric fundamentals
- Underlay network: The physical IP infrastructure that connects fabric nodes. It typically uses OSPF for unicast forwarding and transports encapsulated Overlay traffic without awareness of Overlay services.
- Overlay network: The virtual network built on the Underlay. VXLAN extends Layer 2 and Layer 3 services, and VNIs provide segmentation and tenant isolation.
- Control plane: BGP EVPN distributes MAC and IP reachability. EVPN routes include MAC/IP advertisements and IP prefix routes.
- Data plane: VXLAN encapsulates Ethernet frames in UDP/IP. Fabric nodes perform encapsulation and decapsulation and support symmetric integrated routing and bridging (IRB).
Fabric roles
A Fabric role defines the function that a device performs in the EVPN VXLAN Fabric.
| Role | Primary function |
|---|---|
| Border | Provides connectivity between the Fabric and external networks. |
| Spine | A Spine commonly acts as a BGP route reflector for EVPN routes. It interconnects Leaf and Border switches and provides redundant forwarding paths. |
| Leaf | Connects endpoints or Layer 2 Access switches and operates as a VTEP (VXLAN tunnel endpoint). It supports Layer 2 bridging within VNIs, Layer 3 routing through IRB, ARP suppression, and host mobility. |
| Intermediate | Provides Layer 2 or Layer 3 Underlay transport without terminating the VXLAN Overlay. |
Note: Intermediate devices provide Underlay transit connectivity between Fabric nodes but are not part of the Fabric. They can be managed in Meraki Dashboard as standard devices or operated outside Dashboard management. No Fabric role or EVPN VXLAN configuration is applied to them.
Multi-role configurations
Supported Fabric-capable switches can combine multiple Fabric functions on a single device. Cloud-Managed Fabric supports the following multi-role deployment modes:
Spine-Border: Combines the Spine and Border functions for collapsed-core deployments. The device acts as Spine for the Fabric and provides external network connectivity.
Border-Leaf: Combines the Border and Leaf functions on one device. The device connects endpoints or downstream access switches to the Fabric while also providing connectivity to external networks.
Software requirement: The Border-Leaf role is supported starting with Cisco IOS XE 17.18.5.
Dependencies and requirements
Hardware requirements
Cloud Fabric wired support matrix
| Deployment function | Supported platforms | Minimum software | Fabric participation or role |
|---|---|---|---|
| Traditional Layer 2 Access | Cisco 9350; Catalyst 9300, 9300L, 9300LM, and 9300X; Catalyst 9200, 9200L, and 9200CX; MS390 | IOS XE 17.18.2 | Outside the Fabric |
| Meraki Layer 2 Access | MS130; MS150 | MS 17 or later | Outside the Fabric |
| Fabric Leaf—Distribution Layer or Routed Access | Catalyst 9300; Catalyst 9300L; MS390; Catalyst 9300X; Catalyst 9500 High Performance | IOS XE 17.18.5 | Leaf |
| Fabric core | Catalyst 9300; Catalyst 9300L; MS390; Catalyst 9300X; Catalyst 9500 High Performance | IOS XE 17.18.5 | Spine or Border-Spine |
| Fabric external connectivity—WAN, DMZ, firewall, or other external networks | Catalyst 9300; Catalyst 9300L; MS390; Catalyst 9300X; Catalyst 9500 High Performance | IOS XE 17.18.5 | Border or Border-Leaf |
Cloud Fabric wireless support matrix
| Wireless vendor | Supported access points | Operational mode | Forwarding mode |
|---|---|---|---|
| Cisco | All supported MR and CW access points | Cloud | Distributed |
Recommended platforms
- Spine: Catalyst 9500-24Y4C, 9500-48Y4C, 9500-32C, Catalyst 9300X models
- Border: Catalyst 9500-24Y4C, 9500-48Y4C, 9500-32C, Catalyst 9300X models
- Leaf: Catalyst 9500-24Y4C, Catalyst 9500-48Y4C, and Catalyst 9500-32C for standalone or EVPN Multi-Homing deployments. Catalyst 9300X models with StackWise or EVPN Multi-Homing support, and Catalyst 9300, Catalyst 9300L, and MS390 models
- Access: Cisco or Meraki Layer 2 switches that support SGT/TrustSec, including Cisco 9350; Catalyst 9300, 9300L, 9300LM, and 9300X; Catalyst 9200, Catalyst 9200L, and Catalyst 9200CX; and the MS390, MS150, and MS130 families
- Wireless Access Points: MR and CW Access Points
Software and service requirements
| Requirement | Minimum or recommended value |
|---|---|
| Licensing | Cloud Switching Advanced license for EVPN and Adaptive Policy |
| Management | Cisco Meraki Dashboard, API key and internet access over TCP 443 when API access is used |
| Authentication | Cisco Identity Services Engine (ISE) 3.2 or later, or Cisco Meraki Access Manager |
| Underlay routing | OSPFv2 for unicast routing |
Release support
| Capability | IOS XE 17.18.2 | IOS XE 17.18.5 |
|---|---|---|
| Cloud-managed mode | Managed | Managed |
| Release status | Generally available (GA) | Generally available (GA) |
| Traditional Layer 2 Access platforms | MS and supported Catalyst 9200 and Catalyst 9300 Series switches | MS and supported Catalyst 9200 and Catalyst 9300 Series switches |
| Fabric Leaf—Distribution Layer or Routed Access | Catalyst 9300X | Catalyst 9500 High Performance, Catalyst 9300X, Catalyst 9300, Catalyst 9300L, and MS390 |
| Fabric core—Spine or Border-Spine | Catalyst 9500 High Performance (recommended) and Catalyst 9300X | Catalyst 9500 High Performance (recommended), Catalyst 9300X, Catalyst 9300, Catalyst 9300L, and MS390 |
| Fabric external connectivity—Border or Border-Leaf | Border: Catalyst 9500 High Performance (recommended) and Catalyst 9300X | Border or Border-Leaf: Catalyst 9500 High Performance (recommended), Catalyst 9300X, Catalyst 9300, Catalyst 9300L, and MS390 |
| Leaf redundancy modes | Cisco StackWise | EVPN Multi-Homing and Cisco StackWise |
| Network support | Wired and Distributed Wireless | Wired and Distributed Wireless |
| Segmentation | Macro-segmentation and Micro-segmentation | Macro-segmentation and Micro-segmentation |
| Policy engines | Cisco ISE and Cisco Meraki Access Manager | Cisco ISE and Cisco Meraki Access Manager |
Fabric scale
| Metric | IOS XE 17.18.2 | IOS XE 17.18.5 |
|---|---|---|
| Access points | 300 | 1,000 |
| Distribution blocks (fabric Leaf switches) | 4 | 32 |
| Fabric clients per Distribution Block | 3,000 | 10,000 |
| Access switches (in stacks) | 384 | 768 |
| Fabric subnets | 300 | 300 |
| VRFs | 64 | 64 |
Dashboard device scale
These Dashboard-level limits are separate from the Fabric release-specific scale values above.
| Dashboard device scale | Maximum |
|---|---|
| Devices per Organization | 50,000 |
| Devices per Network (standalone and combined) | 5,000 |
Devices per Network limits
| Product type | Limit |
|---|---|
| Access Points | 5,000 |
| Switches | 5,000 |
The product-specific limits are not additive. A standalone or combined network remains limited to 5,000 total devices.
For additional Dashboard limits and design guidance, see Building a Scalable Meraki Solution.
Fabric reserved interfaces and addresses
Automatic Underlay and Overlay provisioning uses reserved VLANs, Loopbacks, VNIs, and address spaces. Before deployment, confirm that these resources are unused and do not overlap with the existing network. The Underlay address pool can be changed during Fabric creation. A Custom Underlay bypasses automatic Underlay provisioning and does not require the automatic-Underlay VLAN reservation.
| Resource | Default or base value | Allocation or reserved range | Notes |
|---|---|---|---|
| Fabric ID | 1 | 1–256 | Unique fabric identifier |
| VRF ID | 1 | 1–64 | Unique VRF identifier |
| Core VLAN | 965 | 965–1028 | Allocated from the base according to the VRF index |
| Underlay VLAN | 900 | 900–915 | Required only for the routed-SVI automatic Underlay |
| Layer 2 VNI | 10000 | Offset 1–4094 | Derived from the VLAN allocation |
| Layer 3 VNI | 20000 | Offset 1–64 | Derived from the VRF allocation |
| Fabric Loopback | Loopback100 | One per fabric node | Used as the fabric VTEP Loopback |
| Core VLAN Loopback | Loopback200 | Loopback200–263 | Allocated according to the VRF index |
| Anycast RP Loopback | Loopback300 | Loopback300–363 | Used when multicast replication is enabled |
| Route distinguisher | — | <fabric-Loopback-IP>:<core-VLAN-ID> | Automatically derived |
| Route target | — | <fabric-ASN>:<core-VLAN-ID> | Automatically derived |
| Underlay subnet pool | 172.16.0.0/16 | One /24 per Underlay subnet | Customizable during fabric creation |
Fabric design options
A Cloud-Managed EVPN Fabric can be deployed at the Distribution Layer or extended to the Access Layer through a Routed Access design. The primary difference is where the Fabric boundary resides and which switches participate directly in the EVPN VXLAN control plane.
In a Distribution-Layer Fabric, supported Fabric-capable switches operate in the Leaf role at the Distribution Layer. Traditional Layer 2 Access switches remain outside the Fabric and connect to the Distribution Layer through standard Layer 2 uplinks or EVPN Multi-Homing. Endpoint VLANs and Fabric services terminate on the Distribution Layer Leaf switches. This design preserves the existing Access Layer, reduces the number of Fabric nodes, and provides a practical option for brownfield deployments or phased migrations.
In a Routed Access Fabric, supported Access switches operate as Fabric Leaf switches and connect to upstream Spine or Border-Spine devices through routed Layer 3 uplinks. The Fabric extends closer to endpoints, and each Access Layer Leaf switch provides local VXLAN termination, gateway services, and policy enforcement. This design limits Layer 2 failure domains, removes the requirement to extend Layer 2 connectivity between the Access and Distribution Layers, and provides greater path resiliency. It is best suited to greenfield deployments or environments prepared to introduce routed connectivity throughout the Access Layer.
Choose the design based on the existing Access Layer architecture, supported platforms, cabling and uplink design, Layer 2 adjacency requirements, segmentation and mobility objectives, operational model, and desired Layer 3 boundary.
Fabric at the Distribution Layer
In this design, supported Fabric-capable switches operate in the Leaf role at the Distribution Layer and connect to traditional Layer 2 Access switches. The EVPN VXLAN Fabric terminates at Distribution, introducing Overlay segmentation, Distributed Anycast Gateway services, and endpoint mobility while preserving the existing Access architecture. This option suits brownfield environments and phased migrations, providing a path to Fabric segmentation and mobility while existing Access switches and Layer 2 connectivity remain in place.
- Legacy integration: Connects unmanaged or non-Fabric-capable Access switches without requiring immediate Access-Layer replacement.
- Simplified management: Limits the number of VTEPs and reduces configuration scope and potential failure points.
- Scalable external connectivity: Allows Distribution switches to provide Border connectivity to WAN, data centers, and other external networks.
EVPN Multi-Homing at the Distribution Layer
EVPN Multi-Homing is generally available (GA) with IOS XE 17.18.5 at the Distribution Layer. EVPN Multi-Homing allows a Layer 2 Access switch to connect to a pair of Distribution Layer Leaf switches through a common Ethernet segment. The Access-facing links are bundled into a port channel, and both Leaf switches participate in forwarding traffic for the attached Access network.
This active/active design uses the available uplinks more efficiently than an active/standby topology and provides continued connectivity if a link or Distribution switch becomes unavailable. Forwarding is distributed across both members of the EVPN Multi-Homing pair, while EVPN exchanges the reachability information required to coordinate the pair and maintain consistent forwarding behavior. The design preserves the existing Layer 2 Access architecture while adding EVPN VXLAN control-plane resiliency at the Distribution Layer.
Key design capabilities include:
- Active/active forwarding: Both members of the EVPN Multi-Homing pair can forward traffic for the connected Access network, improving link utilization and eliminating dependence on a single active distribution path.
- Distribution-layer resiliency: The loss of one member or one Access-facing link does not require the Access network to depend on a separate standby topology. The surviving member continues forwarding traffic for the Ethernet segment.
- Distributed forwarding: Each member performs local forwarding and participates in the EVPN control plane, reducing reliance on a single Distribution switch.
- Layer 2 access preservation: Existing Access switches can remain connected through port channels while the EVPN VXLAN Fabric terminates on the Distribution Layer Leaf switches.
- Flexible platform selection: Catalyst 9300, Catalyst 9300L, Catalyst 9300X, Catalyst 9500 High Performance, and MS390 switches can form an EVPN Multi-Homing pair. These platforms are supported in the Leaf role for this Distribution-Layer design.
For detailed EVPN Multi-Homing design guidance and requirements, see EVPN Multi-Homing - Cloud-Managed Fabric
Fabric at the Access Layer with Routed Access
In a Routed Access design, Fabric Leaf switches operate at the Access Layer and connect upstream through routed Layer 3 uplinks. The fabric uses multiple available paths between Access Leaf switches and upstream nodes, placing the Layer 3 boundary closer to endpoints and keeping access Layer 2 domains local.
- Routed uplinks: Use Layer 3 links from Access Leaf switches to upstream Fabric nodes without extending a Layer 2 access domain to distribution.
- Active/active path use: With ECMP (Equal-Cost Multi-Path) across independent uplinks, multiple paths can forward traffic at the same time.
- Failure resiliency: If an uplink or upstream path fails, traffic uses a surviving route after routing converges.
- Layered design: Keep access and upstream Fabric roles distinct while limiting Layer 2 adjacency to the access segment.
Combined Spine-Border roles: In a collapsed upstream design, the Spine and Border functions run on the same pair of Fabric nodes. Each Access Layer Leaf uses independent routed uplinks to both combined-role nodes, providing ECMP path utilization and maintaining upstream connectivity after a single link or node failure. Use this option when the selected platforms and validated scale support the combined Spine-Border role.
Fabric handoff
The Border uses the Underlay for Dashboard management reachability and provides the Overlay handoff that connects Fabric client VLANs to networks outside the Fabric. Two handoff modes are supported: BGP-based VRF-Lite and static routes. Choose the mode according to the routing integration at the external domain.
BGP-based VRF-Lite handoff
With BGP-based VRF-Lite, BGP peers exchange routes between Fabric VRFs and the external routing domain while keeping routing contexts separate. Use this mode when the external domain participates in dynamic BGP route exchange.

“Create L3 interface” is used to create an SVI or routed interface for the handoff, and “Create eBGP Peer” creates a VRF-Lite eBGP handoff to the external domain.
Static route handoff
A static route handoff is an alternative to the BGP-based VRF-Lite Border handoff. It connects Fabric VRFs to external networks without establishing a dynamic routing adjacency between the Fabric Border and the external routing device. This option is appropriate when the external network does not support BGP, when only a small and stable set of prefixes must be exchanged, or when the existing network design uses static routing.
Static routes are not created through the Fabric workflow. Skip the Border handoff step, complete Fabric provisioning, and then configure the required Layer 3 connectivity and routes through Switching > Routing & DHCP in Meraki Dashboard. Create the static route in the appropriate VRF and specify the next-hop address of the external router, firewall, or upstream device.
The external device must also have a return route for the Fabric prefixes. Depending on the design, this can be a route for each Fabric subnet, a summarized route, or a default route. Forward and return routing must be configured correctly before Fabric clients can communicate with external networks.
Consider the following when using a static route handoff:
- VRF association: Configure each static route in the VRF that contains the Fabric subnets requiring external connectivity.
- Next-hop reachability: The Border must be able to reach the configured next-hop address through the handoff interface.
- Return routing: Configure the external device with routes back to the Fabric prefixes through the Border.
- Route maintenance: Static routes do not automatically respond to topology or prefix changes. Update both sides of the handoff whenever prefixes or next-hop addresses change.
- Redundancy: When multiple Borders or upstream devices are used, configure the required routes and failure-detection behavior according to the redundancy design.
- Scale: Static routing is best suited to environments with a limited and predictable set of prefixes. Use BGP-based VRF-Lite when dynamic route exchange, larger route tables, or faster adaptation to routing changes is required.
After configuration, verify that the Border can reach the external next hop, that external devices have routes back to the Fabric subnets, and that clients in each affected VRF have bidirectional connectivity.

Network segmentation
Cloud-Managed Fabric provides two complementary levels of segmentation across a shared physical infrastructure. VRFs provide Layer 3 isolation between virtual networks, while SGT-based policy controls communication between users, devices, and applications within those networks.
Macro-segmentation (VRF)
Macro-segmentation uses virtual routing and forwarding (VRF) instances to create Layer 3 isolation between forwarding domains. Multiple virtual networks can share the same physical infrastructure while maintaining separate routing tables.
- Provides Layer 3 isolation through VRF instances.
- Supports up to 64 VRF instances per organization.
- Supports creation of VRFs at scale through Meraki Dashboard fabric workflows.
Micro-segmentation (SGT)
Micro-segmentation provides role-based access control between groups within a virtual network. It can separate lines of business, user roles, device classes, or functional blocks without requiring a separate subnet for every policy boundary.
- Uses Security Group Tags (SGTs) and Adaptive Policy.
- Supports dynamic and static SGT mappings.
- Integrates with Cisco Meraki Access Manager or Cisco Identity Services Engine (ISE).
- Extends policy within the fabric and, where supported, beyond the fabric.
- To enable micro-segmentation, configure Adaptive Policy groups and their associated SGT values, define the permitted traffic between groups, and enable Adaptive Policy on the required Dashboard networks. Refer to the Adaptive Policy Configuration Guide for licensing and platform prerequisites, organization-wide group and policy configuration, custom ACLs, and network enablement.
- For switch-level configuration, refer to the Adaptive Policy MS Configuration Guide. It explains SGT classification and propagation, Peer SGT Capable links, static port-to-SGT assignments, VLAN-to-SGT mappings, and dynamic SGT assignment through RADIUS. Before enabling policy enforcement, verify that all participating devices meet the applicable licensing, software, and platform requirements and that SGT propagation is enabled on the required inter-device links.
Fabric Overlay routing
The architecture supports three Overlay subnet types. Each option addresses different requirements for Layer 2 reachability, Layer 3 gateway placement, scalability, and failure-domain size.
| Subnet type | Scope and gateway | BUM behavior | Best suited for |
|---|---|---|---|
| Routed | Layer 3 subnet on one Leaf. It cannot stretch across Leaf switches. | No cross-Leaf Layer 2 flood domain. | Highly scalable local subnets. Subnets must be unique; VLAN IDs do not need to match. |
| DAG routed | Layer 3 subnet stretched across selected Leaf switches through a Distributed Anycast Gateway. | Flood-free stretch between Leaf switches; BUM replication is restricted to the Access side. | Scalable wired and wireless client VLANs that require mobility. The same VLAN ID and Layer 3 subnet are used on participating Leaf switches. |
| DAG bridged | DAG routed plus Layer 2 flooding across selected Leaf switches. | BUM traffic is replicated across participating Leaf switches. | Legacy non-IP endpoints, silent hosts, and AP management VLANs that require Layer 2 flooding. Use selectively because it enlarges the flood domain. |
Terminology: BUM means broadcast, unknown-unicast, and multicast traffic. DAG means Distributed Anycast Gateway.
Routed subnet
A routed subnet exists on a single Leaf and cannot be stretched across multiple Leaf switches. It is the most scalable option when Layer 2 adjacency across Leaf switches is not required.
- Gateway and scope: A Layer 3 subnet exists on one Leaf and is not stretched.
- BUM behavior: BUM traffic remains local to the Leaf.
- VLAN and subnet requirements: Subnets must be unique; VLAN IDs do not need to match across Leaf switches.
- Recommended use: Use this as the default when subnet mobility is not required.
- Scale profile: Highly scalable.
Routed Overlay with independent Layer 3 subnets on two Leaf switches.
DAG Routed
A DAG-routed subnet stretches a Layer 3 subnet across selected Leaf switches while avoiding a cross-Leaf Layer 2 flood domain. It is recommended for scalable wired and wireless client VLANs and supports mobility across targeted indoor and outdoor wireless coverage areas.
- Gateway and scope: A Layer 3 subnet is stretched across selected Leaf switches using a Distributed Anycast Gateway.
- BUM behavior: BUM replication is restricted to the access edge and is not bridged between Leaf switches.
- VLAN and subnet requirements: Participating Leaf switches use the same VLAN ID and Layer 3 subnet.
- Recommended use: Choose this for IP endpoints and seamless wired or wireless mobility without extending the Layer 2 flood domain.
- Scale profile: Scalable across medium-to-large networks.
DAG Bridged
A DAG-bridged subnet adds Layer 2 BUM replication across selected Leaf switches. Use it only for workloads that require a shared flood domain, because it consumes more resources and increases the failure-domain size.
- Gateway and scope: A Layer 3 subnet is stretched across selected Leaf switches using a Distributed Anycast Gateway.
- BUM behavior: Layer 2 BUM traffic is replicated across participating Leaf switches.
- VLAN and subnet requirements: Participating Leaf switches use the same VLAN ID and Layer 3 subnet.
- Recommended use: Use this selectively for non-IP endpoints, silent hosts, and applications that require Layer 2 flooding.
- Scale profile: Lower scalability; use selectively.
Configuration guidance: The Overlay subnet type and its associated Anycast Gateway and Broadcast Replication settings are selected when creating or editing a Fabric subnet. See Step 3: Create subnets in the Fabric creation workflow for instructions on configuring Routed, DAG Routed, and DAG Bridged Overlay subnets.
Fabric wireless
Distributed wireless with fabric
Distributed wireless with Fabric extends wireless VLANs across selected Fabric Leaf switches while maintaining efficient traffic forwarding. Use DAG Bridged selectively for the AP management VLAN when Layer 2 flooding is required, and use DAG Routed for client VLANs to provide flood-free IP subnet stretch. This architecture supports seamless client mobility across the wireless coverage area while limiting broadcast domains and improving overall Fabric scalability.
A scalable wireless architecture maintains client connectivity and supports seamless mobility throughout the wireless coverage area. DAG Routed subnets provide flood-free IP subnet stretch for client VLANs, limiting unnecessary Layer 2 flooding across the core and Access Layers while improving network efficiency and scalability.
Distributed wireless
In a Routed Access design, the Fabric Leaf function moves to the Access Layer. Each Access-layer Leaf switch connects to the upstream Fabric through routed uplinks, terminates the VXLAN Overlay, and provides local gateway services for its attached access points and clients.
Distributed wireless uses the same Overlay service models in both designs. Use DAG Routed client subnets across selected Routed Access Leaf switches to create a flood-free mobility domain, and use DAG Bridged only for an AP management VLAN or another workload that requires Layer 2 flooding. Subnet placement across the Routed Access Leaf switches defines the roaming scope. Extend the client subnet only to Leaf switches that serve the intended coverage area.
Wireless mobility design best practices
- Align each client subnet with its required mobility domain. The set of Fabric Leaf switches on which a DAG Routed subnet is provisioned defines where that subnet is available and, therefore, the area across which clients can retain their IP address while roaming.
- Keep the subnet local when mobility is limited to one Distribution Block. If seamless roaming is required only between access points connected within the same Distribution Block, provision the client subnet only on the Leaf switches serving that block. This approach limits the scope of the subnet, simplifies operations, and avoids extending it to Fabric nodes where it is not required.
- Extend the subnet across Distribution Blocks when a larger mobility domain is required. If clients must roam seamlessly between access points connected to different Distribution Blocks, provision the same DAG Routed subnet on the Leaf switches serving each required block. This creates a broader IP mobility domain and allows clients to retain their IP address and session continuity as they move across the covered area.
- Avoid extending client subnets beyond the intended wireless coverage area. Subnet placement should follow actual roaming requirements rather than automatically spanning every Fabric Leaf. Selective extension reduces the operational scope of each subnet and improves overall Fabric scalability.
- Limit DAG Bridged subnets to use cases that require Layer 2 flooding. The AP management VLAN may use DAG Bridged when AP discovery or other management functions require Layer 2 flooding across Leaf switches. Because DAG Bridged expands the Layer 2 flood domain, extend it only to the Distribution Blocks containing APs that use that management VLAN.
Underlay design considerations
The Underlay is the physical IP transport network that provides connectivity between Fabric nodes and carries the VXLAN-encapsulated Overlay traffic. A successful Underlay design must provide resilient IP reachability between Leaf, Spine, and Border nodes, including reachability to the Fabric Loopback interfaces used by the VTEPs. The design should account for VXLAN MTU overhead, the routed links or SVIs used between nodes, OSPF neighbor establishment and route exchange, IP address allocation, path redundancy, and the required Underlay VLANs on trunk links. These elements must be configured and validated before the Overlay is deployed because Underlay reachability and stability directly affect EVPN control-plane operation and VXLAN data-plane forwarding.
MTU considerations
- VXLAN adds approximately 50 bytes of encapsulation overhead.
- Use a larger MTU throughout the Underlay to prevent fragmentation or drops.
- Configure an MTU of 9100 or 9198 bytes consistently across Fabric switches.
Underlay with routed ports (recommended)
- Recommended for Fabric deployments.
- Use the Meraki Dashboard Routing & DHCP workflow to create routed links between Leaf, Spine, and Border nodes.
- Enable OSPF on the routed interfaces to provide Underlay connectivity.
- Routed-port Underlay configuration is performed outside the Fabric workflow. Enable Custom Underlay when provisioning the Fabric.
Underlay with SVIs (Brownfield)
- Use this option when distribution-to-core links cannot be converted to routed ports.
- Fabric workflows automate the Underlay SVI and OSPF configuration.
- Underlay routing uses VLANs 900–915. Allow these VLANs on the uplink trunk ports.
- The Underlay IP pool is customizable; the default is 172.16.0.0/16.
DHCP relay for Overlay subnets
DHCP relay forwards client requests from Overlay subnets to a DHCP server; select the Global VRF for a shared server or the VLAN VRF for a tenant-scoped server.
DHCP server in global table
A DHCP server in the global routing table can provide a shared service to clients in multiple fabric tenant VRFs.
The server must be reachable from the Border through the Underlay. Relay requests are sourced from Loopback100 on Leaf devices, so the Loopback100 address pool must be reachable from the external domain to provide the return path for DHCP responses to the originating Leaf. For Cisco IOS XE EVPN/VXLAN DHCP server configuration examples, see Configure DHCP in IOS XE EVPN/VXLAN
DHCP server in tenant VRF
Each device uses a loopback interface in the tenant VRF as the DHCP relay source. The DHCP server must be reachable through that VRF and have a return path to the relay-source loopback so that replies can reach the Leaf. This keeps DHCP relay traffic within the tenant routing context rather than using the global routing table.
Automatic Underlay provisioning
Automatic Underlay provisioning configures connectivity between Fabric nodes by using reserved VLANs and IP pools. It is performed as part of the Fabric workflow when Custom Underlay remains unchecked.
- VLANs 900–915 are reserved for Automatic Underlay provisioning.
- Spine-to-Border links use even VLAN IDs, such as 900 and 902.
- Spine-to-Leaf links use odd VLAN IDs, such as 901 and 903.
Underlay VLAN mapping
| Underlay VLAN ID | Non-routed subnet | Description |
|---|---|---|
| 900 | 172.16.0.0/24 | Spine A to Border |
| 901 | 172.16.1.0/24 | Spine A to Leaf |
| 902 | 172.16.2.0/24 | Spine B to Border |
| 903 | 172.16.3.0/24 | Spine B to Leaf |
Automatic Underlay requirements
- Enable Rapid Per-VLAN Spanning Tree Plus (RPVST+) at the network level and prune VLANs so that the count remains below 300.
- Configure the physical links and VLAN membership between switches using SmartPorts or named VLANs.
- Combined Border/Spine roles can simplify the Underlay topology in Collapsed Core environments.
| Connection | Purpose and requirements |
|---|---|
| Management or uplink interface (Underlay) | Provides Dashboard connectivity. An SVI-based uplink is the default. A routed-port uplink requires a dedicated front-panel port, and a second routed port can provide backup connectivity. |
| Fabric Handoff (Overlay) | Carries traffic into and out of the Fabric VRF. SVI and routed Layer 3 interfaces are supported. Configure eBGP after creating the interface to enable dynamic routing. |
| DHCP relay and Loopback100 pool reachability | The DHCP server must be reachable from the Border through the Underlay. DHCP relay requests originate from Loopback100 on Leaf switches; the Loopback100 address pool must be reachable from the external domain to provide the return path to the Fabric. |
Identity and Access Policy
Identity-based access uses user and device information to determine network access. This section summarizes how Cisco Meraki Access Manager and Cisco ISE support authentication and policy enforcement for Fabric endpoints.
Access policies can be defined under Switching > Configure > Access policies.
Cisco Meraki Access Manager
Cisco Meraki Access Manager provides cloud-delivered access control for identity-based micro-segmentation and zero-trust adoption.
- Flexible authentication: Supports wired and wireless users, computers, and Internet of Things devices.
- Secure RADIUS transport: Uses Cisco-managed encrypted TLS tunnels to Meraki Dashboard.
- Multitenant software as a service: Provides globally delivered availability and scale.
Supported device capabilities
| Model or family | 802.1X | MAB | VLAN | GPACL | TrustSec |
|---|---|---|---|---|---|
| Wireless: MR20, MR70 (MR 30.7+) | Yes | Yes | Yes | Yes | — |
| Wireless: 802.11ac Wave 2, 802.11ax, Wi-Fi 7 (MR 30.7+) | Yes | Yes | Yes | Yes | Yes |
| Switching: MS120, MS125, MS130 (MS 17+) | Yes | Yes | Yes | — | — |
| Switching: MS390, C9K-M (CS 17.1+) | Yes | Yes | Yes | Yes | Yes |
| Switching: Catalyst 9200 and Catalyst 9200CX, Catalyst 9300, Cisco 9350, Catalyst 9500 High Performance (IOS XE 17.18.1+) | Yes | Yes | Yes | Yes | Yes |
GPACL = group-based policy access control list, MAB = MAC Authentication Bypass.
Please refer to Switch Port Access Policy to create Access policies that use Access Manager. For more information, see Cisco Meraki Access Manager documentation.
Cisco Identity Services Engine
Cisco Identity Services Engine (ISE) provides centralized identity-based access control and policy administration for wired and wireless endpoints within the Fabric. Through standards-based RADIUS services, ISE authenticates users and devices using methods such as 802.1X and MAC Authentication Bypass (MAB), then applies authorization policies based on identity, device type, security posture, location, and other contextual information. Authorization results can dynamically assign VLANs, downloadable access control lists, and Cisco TrustSec Security Group Tags (SGTs). SGTs enable role-based micro-segmentation by classifying endpoints independently of their IP addresses or physical locations, while Security Group Access Control Lists (SGACLs) define which groups may communicate. ISE can also use Change of Authorization (CoA) to update active sessions when an endpoint’s authorization or security state changes. This integration provides consistent access policy and segmentation across supported Fabric switches and wireless platforms, with feature availability determined by the platform, software release, and selected enforcement method.
For ISE authorization policies that return a named VLAN, enable Named VLANs for use with RADIUS in the Dashboard network.
Go to Network-wide > Configure > VLAN profiles > Settings, select Enable Named VLANs for use with RADIUS, and save the change.
Then configure the VLAN with a name that matches the named VLAN returned by ISE in its RADIUS authorization response. This allows the Fabric switch to map the returned name to the intended VLAN instead of relying on a numeric VLAN ID.
For additional information, see Adaptive Policy and Cisco ISE and How to integrate Meraki networks with ISE and VLAN Profiles.
Fabric creation workflow
The following illustrated sequence maps the Meraki Dashboard workflow from fabric definition through staging and deployment. The callouts show the controls used at each step.
Note: The values shown in the workflow screenshots are examples. Use addressing, AS numbers, VLAN IDs, VRFs, and device selections appropriate for your deployment.
Step 1: Create a Fabric topology
- In Meraki Dashboard, navigate to Organization > Configure > Fabric to create a fabric.
- Name the Fabric and select the networks to include.
- Use the network selection to control which switches appear in the role-assignment table. Select multiple networks when the Fabric must span more than one network.
- Assign each device a single role or a supported multi-role combination.
- Underlay Loopback IP pool: Used to create Loopbacks. It must be routable through the Underlay.
- Underlay core IP pool: Used for automatic Underlay VLANs 900–915.
- Custom Underlay: Disables automatic Underlay provisioning so that an existing Underlay or routed ports can be used.
Create VRFs
- Click Add VRF and create VRFs.
- A VRF created outside the Fabric workflow cannot be reused.
Step 3: Create subnets
- Define the VLAN, gateway IP address and subnet mask, DHCP server, and Overlay type.
- By default, a new subnet uses an Anycast Gateway for DAG Routed operation. Enable Broadcast Replication to create a DAG Bridged subnet. Disable both Anycast Gateway and Broadcast Replication to create a Routed subnet.
- Select the Leaf switches on which the subnet must be provisioned. A Routed subnet is limited to one Leaf; DAG subnets can span multiple Leaf switches.
- Provide an external DHCP server for fabric clients that require DHCP.
- Use a unique VLAN ID that does not conflict with an existing SVI or VLAN.
Step 4: Configure Border handoff
- Create a Layer 3 interface on each Border. SVI and routed-port interfaces are supported. For an SVI-based handoff, allow the selected VLAN on the trunk interface.
- Configure the eBGP peer after creating the Layer 3 interface.
Step 5: Preview, Stage, and Deploy
- Review the proposed configuration changes.
- Return to the workflow to make corrections, or save the configuration to staging.
- Schedule an appropriate change window, or select Deploy Now to deploy the configuration immediately.
- Monitor the Fabric and migrate Underlay subnets as required.
EVPN Multi-Homing creation workflow
Starting with Cisco IOS XE 17.18.5 or 26.1.1, EVPN Multi-Homing can be enabled on Catalyst 9300X or Catalyst 9500 High Performance Distribution switches. An EVPN Multi-Homing pair preserves the existing Layer 2 access design while providing active/active forwarding, independent management and control planes, and distributed forwarding across the two Leaf switches.
Follow these steps to create an EVPN Multi-Homing pair.
- Under Switching, select EVPN Multi-Homing.
- Select Create EVPN-MH pair, name the pair, and choose the two switches that will form it.
- Under Configure your EVPN-MH pair, enter the BGP autonomous system number. Ensure that it matches the Fabric BGP AS number.
- Choose a Loopback interface for each member. Loopback100 is reserved for the Fabric and cannot be used.
- Assign a /32 Loopback IP address for BGP peering to each member. For example, 10.1.0.1/32.
- Select the interfaces that form the inter-member port channel. A minimum of two interfaces is required.
- Assign a /31 or /30 IP subnet to the inter-ES link.

Add the EVPN Multi-Homing pair to the Fabric
- In the selected Fabric workflow, under Device Roles, select Add Device.
- Choose the network that contains the EVPN Multi-Homing pair, then select the pair.
- Assign the Leaf role to the pair and make the required Fabric subnets available on it.

Create downstream port channels
- Navigate to Switching > Switch ports.
- On the Access switch, filter by switch name, select the required ports, and select Aggregate.
- On the EVPN Multi-Homing pair, select both Leaf devices and their corresponding ports, then select Aggregate.
Fabric assurance
Meraki Dashboard provides a consolidated assurance view that enables administrators to assess the operational health of the Fabric from a single location. Fabric-role summaries show the deployment and status of Leaf, Spine, and Border nodes, including devices operating in combined roles, allowing administrators to verify that the intended topology is present and operational. VRF summaries provide visibility into the Layer 3 segmentation domains configured across the Fabric and help confirm that the required virtual networks are available on the appropriate Fabric nodes.
The assurance view also provides insight into the EVPN VXLAN control plane and data plane. BGP neighbor status helps administrators validate peer relationships between Fabric nodes and external handoff devices, making it easier to identify failed adjacencies or routing problems. VXLAN tunnel status provides visibility into VTEP connectivity between Fabric nodes and helps identify tunnel or Underlay reachability issues that could affect Overlay forwarding. Together, these views support faster fault isolation by helping administrators determine whether an issue is associated with a Fabric node, VRF, BGP adjacency, VXLAN tunnel, or the underlying transport network.
Troubleshooting checklist
| Check | Validation |
|---|---|
| Device firmware | Verify IOS XE 17.18.2 or later, as applicable to the feature set. |
| Network-level settings | Verify that RPVST+ is enabled and VLANs are pruned to fewer than 300. |
| Underlay connectivity | Verify OSPF adjacencies and Loopback reachability. |
| BGP EVPN | Verify BGP neighbor state and EVPN route exchange. |
| VXLAN tunnels | Verify the NVE interface and VTEP peers. |
| Fabric subnets | Verify DAG reachability and VNI mappings. |
| Client connectivity | Test client-to-client reachability and DHCP operation. |
| Dashboard synchronization | Verify that the switch configuration updater is synchronized. |
Run EVPN CLI commands from Dashboard
Meraki Dashboard provides switch-level CLI runners for predefined operational commands. Administrators can use these runners to collect BGP EVPN and NVE/VXLAN output directly from a Fabric switch without opening a separate terminal session or connecting to the device through an external CLI client. This provides a consistent way to validate control-plane state, VNI information, peer relationships, and EVPN route information during routine verification and fault isolation.
- Go to Switching > Monitor > Switches and select the Fabric switch that you want to inspect.
- Select the Tools tab on the switch details page.
- Under Show BGP/EVPN CLI, select the required operational command and select Run. Available selections include BGP L2VPN EVPN route and summary views, recursive next-hop information, NVE VNIs, and NVE peers.
- Review the returned output on the same page. Repeat the command on other relevant Leaf, Spine, or Border switches when you need to compare state across the Fabric.
Common CLI commands
# Verify BGP EVPN neighbors
show bgp l2vpn evpn summary
# Check VXLAN NVE peers
show nve peers
# Verify VNI mappings
show nve vni
# Check EVPN Type 2 routes
show bgp l2vpn evpn route-type 2
# Verify the anycast gateway
show l2vpn evpn default-gateway
# Check EVPN EVI details
show l2vpn evpn evi detail
# Verify Loopback interfaces
show ip interface brief | include Loopback