MV23 Installation Guide
MV23 Series Overview
The Cisco Meraki MV23 series are network cameras that are exceptionally simple to deploy and configure due to their integration into the Meraki Dashboard and cloud-augmented edge storage. The MV family eliminates complex and costly servers and video recorders required by traditional solutions, removing the limitations typically placed on video surveillance deployments.
Package Contents:
Unit |
MV23-HW |
Mounting Equipment |
1 x base mount plate small 1 x conduit adapter |
MV23 series does not ship with mounting screws and anchors as an included accessory in the packaging content.
Screw Recommendation:
-
Type: Self-Tapping Screw
-
Size: M4
-
Length: Minimum 25mm
-
Screw head diameter: Maximum 10mm
-
Driver Type: ANY (eg: Philips)
-
Head Type: ANY (Eg: Pan Head)
-
Build Material: Stainless Steel
Note: The insertion diameter of the anchor should be smaller than that of the screw, and the length of the anchor should be longer than that of the screw. The appropriate anchor should be selected based on the structure that it will be installed on, such as concrete, brick, wood, drywall, etc.
Powering the MV23 Series
The MV23 features a 1000BASE-TX Ethernet port and requires 802.3at PoE+ minimally for operation. Route the Ethernet cable from an active port on a PoE switch or injector.
Note: Power over Ethernet supports a maximum cable length of 300 ft (100 m).
Pre-Install Preparation
You should complete the following steps before going on-site to perform an installation:
Configure Your Network in the Dashboard
The following is a brief overview of the steps required to add an MV23 series camera to your network. For detailed instructions about creating, configuring and managing Meraki Camera networks, refer to the online documentation (https://documentation.meraki.com/MV).
-
Login to http://dashboard.meraki.com. If this is your first time, create a new account.
-
Find the network to which you plan to add your cameras or create a new network.
-
Add your cameras to your network. You will need your Meraki order number (found on your invoice) or the serial number of each camera, which looks like Qxxx-xxxx-xxxx and is found on the bottom of the unit.
-
Verify that the camera is now listed under Cameras > Monitor > Cameras.
Check and Configure Firewall Settings
If a firewall is in place, it must allow outgoing connections on particular ports to IP addresses. The most current list of outbound ports and IP addresses for your organization can be found under Help>Firewall Info on the dashboard.
DNS Configuration Best practices for LAN Streaming
Each camera will generate a unique domain name for secured direct streaming functionality. These domain names resolve an A record for the private IP address of the camera. Any public recursive DNS server will resolve this domain.
If utilizing an on-site DNS server, please whitelist *.devices.meraki.direct or configure a conditional forwarder so that local domains are not appended to *.devices.meraki.direct and that these domain requests are forwarded to Google public DNS.
Assigning IP Addresses
Currently, the MV23 series camera does not support static IP assignment. MV23 units must be added to a subnet that uses DHCP and has available DHCP addresses to operate correctly.
Installation Instructions
Note: During first-time setup, the MV23 series will automatically update to the latest stable firmware. Some features may be unavailable until this automatic update is completed. This process may take up to 5 minutes to enable whole disk encryption. The state of this process can be monitored by referencing the MV LED Status.
Mounting Instructions
For most mounting scenarios, the MV23 wall mount provides a quick, simple, and flexible means for mounting your device. The installation should be done in a few simple steps:
Note: Leave the protective plastic cover on the optical dome throughout the installation process to prevent any damage to the dome. The protective cover should be removed once the installation is completed.
Microphone Cut-off Switch:
The MV23 Series has a new microphone cut-off switch at the camera's base. This switch can be used to disable audio and override the Dashboard Audio Settings for an added layer of security. If the regulations require disabling audio or Dashboard control for Audio enablement needs to be disabled, the microphone cut-off switch can be leveraged and set to Disabled.
Note: If the microphone switch is disabled and the camera is mounted, toggling the switch back ON would require accessing the camera's base.
1. Use the template to determine mounting hole locations for wall mounting before screwing in the base mount plate. Peel backing from the mounting template to stick on the wall. Use template holes marked with the letter “A” for standard wall mounting. Screw the base mount plate onto the wall in predetermined locations using the recommended wall screws.
Factory Reset Button:
The factory reset button for MV23 series is located on the front of the camera, under the dome.
MV23 Mount using small base plate:
-
Mount the small base plate onto the wall surface using the paper template provided.
-
Use 3x Wall anchor and screws to fix the base plate to the wall.
-
The MV23 Series cameras have a button to engage the locking mechanism. Press the button while aligning the camera to the small base plate.
-
Twist the camera while holding the button until a click is heard.
-
The camera is locked onto the plate and secured.
-
Remove the protective cover
-
Observe the status LED on the top side of the camera lens assembly and ensure the camera is connected via Ethernet (solid green) or WiFi (solid blue).
An MV must first be provisioned over a wired Ethernet connection before it can be deployed wirelessly. See the setup guide here for information on how to connect via WiFi.
MV23 LED Status Indicator
Your MV23 series is equipped with an LED light on the front of the unit to convey system functionality and performance information.
The following colours and patterns indicate the various status conditions of an MV:
-
Rainbow (solid, rotating through colours) - MV is booting up.
-
Flashing Blue - MV is searching for WiFi network(s).
-
Flashing Green - MV is upgrading or initialising for the first time.
-
Solid Green - MV is connected via Ethernet.
-
Solid Blue - MV is connected via WiFi.
-
Solid Violet - MV has audio recording enabled.
-
Solid Amber - MV is not able to connect to the Dashboard.
6. Aim the lens. Look through the camera on the Meraki Dashboard to fine-tune the picture. The camera sensor and lens unit can be physically tilted through 65 degrees, rotated through a range of +/-90 degrees, and panned through 354 degrees. The image can only be rotated by 180 degrees in software, and no other adjustments can be made. Zoom and focus can be adjusted remotely and can not be adjusted physically on the camera. For more information on zooming, refer to the adjusting the Field of View article.
Note: Never adjust or remove the rubber lens gasket or protective lens guard.