Skip to main content
Cisco Meraki Documentation

MS130 Datasheet

Overview 

Cisco Meraki MS130 switches provide Layer 2 access switching, ideal for branch and campus deployments. The MS130 series features a variety of options designed to meet the diverse needs of branch and campus deployments. 

With 10 different models, capable of providing up to 740W of power over a variety of port densities, including SFP+ capable uplinks, the MS130 line is fully ready to support future wireless infrastructure deployments across a variety of different environments.

MS130_family_DSC09651_NoRugged_shadow.png

Features 

  • Managed via Cisco Meraki Dashboard 
  • Remote Packet Capture Tools via Meraki Dashboard
  • Automatic Firmware upgrades 
  • SNMP/Syslog Integration 
  • IPv4/6 ACL support 
  • 802.1Q VLAN tagging  
  • DHCP Snooping 
  • 802.1X Authentication
  • 10/100/1000 Mbps RJ45
  • 2.5GbE RJ45
  • 4x 10 Gbe SFP+ models available 
  • 802.3bt PoE up to 30W per port

Configuration 

The basic initial configuration of the MS130 is just as simple as any other model of MS switch. The links below provide additional information and instructions relating to each step in getting the device setup and configured for the first time. 

  1. Claim the device to an Organization on the Meraki Dashboard
    1. If a Dashboard Organization does not yet exist, Create one
  2. Add the device to a Dashboard Network 
    1. If a Network does not yet exist, Create one first
  3. Physically connect the device to the local network
    1. Connect one of the RJ45 or SFP/SFP+ ports to existing infrastructure to provide a temporary uplink
    2. Power on the device and let it check in to the Dashboard
    3. If necessary, configure a Static IP through the Local Status Page to allow it to communicate with the Meraki Dashboard.
  4. Allow the device to complete check-in and perform any initial firmware upgrades
  5. Finish configuring the device from the Meraki Dashboard 
    1. Manage local VLANs / Port configuration

Technical Breakdown  

Hardware Breakdown

MS130 Models

  MS130-8 MS130-8P MS130-8X MS130-12X
1Gbe RJ45 8 8 6

8

mGbe RJ45 - - 2 x 2.5G 4 x 2.5G

1 Gbe SFP

2 2 - -
10GbE SFP+ - - 2 2
Dedicated Mgmt Interface - - - -
PoE Type   802.3bt 802.3bt 802.3bt
PoE Port Budget   30W 30W 30W
PoE Switch Budget - 120W 120W 240W
Power Input 12VDC, 2.5A 54VDC, 2.78A

54VDC, 2.78A

54VDC, 5.56A

Power Load (idle/max)

8W/8W 8W/128W 16W/136W 19W/260W
Operating Temperature 32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C

Storage and Transportation Temperature

-4°F - 158 °F
-20°C - 70°C

-4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
Humidity 5% to 95% 5% to 95% 5% to 95% 5% to 95%
Mounting

Desktop

Integrated Wall mount 

Desktop

Integrated Wall mount

Desktop

Integrated Wall mount

Desktop

Integrated Wall mount

Switching Capacity 20 Gbps 20 Gbps 62 Gbps 76 Gbps
Power Supply External External External External
Fan Operation Fanless Fanless Fixed Internal Fixed Internal
Dimensions (h x w x d)

1.1 x 8.74 x 6in

(2.8 x 22.2 x 15cm)

1.1 x 8.74 x 6in

(2.8 x 22.2 x 15cm)

1.75 x 9 x 8.58in

(4.4 x 23 x 23cm)

1.75 x 9 x 8.58in

(4.4 x 23 x 23cm)

Weight 1.94 lb (0.88 kg) 1.94 lb (0.88 kg) 2.12 lb (0.96 kg) 2.34 lb (1.06 kg)

 

  MS130-24 MS130-24P MS130-24X MS130-48 MS130-48P MS130-48X
1Gbe RJ45 24 24 18 48 48 40
mGbe RJ45 - - 6 x 2.5G - - 8 x 2.5G
1Gbe SFP 4 4 - 4 4 -
10Gbe SFP+ - - 4 - - 4
Dedicated Mgmt Interface 1 1 1 1 1 1
PoE Type   802.3bt 802.3bt   802.3bt 802.3bt
PoE Port Budget   30W 30W   30W 30W
PoE Switch Budget - 370W 370W - 740W 740W
Power Input 100-240V~, 1.5-0.85A, 50-60Hz 100-240V~, 8A-4A, 50-60Hz 100-240V~, 8A-4A, 50-60Hz 100-240V~, 1.5-0.85A, 50-60Hz 100-240V~, 12-6A, 50-60Hz 100-240V~, 12-6A, 50-60Hz
Power Load (idle/max) 15W/15W 32W/406W 50W/421W 28W/28W 49W/803W 60W/808W
Operating Temperature 32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
32°F - 113 °F
0°C - 45°C
Storage and Transportation Temperature -4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
-4°F - 158 °F
-20°C - 70°C
Humidity 5% to 95%     5% to 95%     5% to 95%     5% to 95%     5% to 95%     5% to 95%    
Mounting Integrated 1U Rack Mount Integrated 1U Rack Mount Integrated 1U Rack Mount Integrated 1U Rack Mount Integrated 1U Rack Mount Integrated 1U Rack Mount
Switching Capacity 56 Gbps 56 Gbps 146 Gbps 104 Gbps 104 Gbps 200 Gbps
Power Supply Fixed Internal Fixed Internal Fixed Internal Fixed Internal Fixed Internal Fixed Internal
Fan Operation Fanless Fixed Internal Fixed Internal Fanless Fixed Internal Fixed Internal
Dimensions

1.73 x 17.32 x 10in

(4.4 x 44 x 25cm)

1.73 x 17.32 x 10in

(4.4 x 44 x 25cm)

1.73 x 17.32 x 10in

(4.4 x 44 x 25cm)

1.73 x 17.32 x 10in

(4.4 x 44 x 25cm)

1.73 x 17.32 x 13.4in

(4.4 x 44 x 34cm)

1.73 x 17.32 x 13.4in

(4.4 x 44 x 34cm)

Weight 7.19 lb (3.26 kg) 8.91 lb (4.04 kg) 9.37 lb (4.25 kg) 8.14 lb (3.69 kg) 12.13 lb (5.5 kg) 12.59 lb (5.71 kg)

 

Whats In the Box

Model Included
MS130-8, 8P, 8X, 12X MS130 switch, AC Power Supply
MS130-24, 24P. 24X, 48, 48P, 48X MS130 switch

Region-specific power cords are not included in the box*. Order the appropriate power cord separately:

  • MA-PWR-CORD-US
  • MA-PWR-CORD-EU
  • MA-PWR-CORD-UK
  • MA-PWR-CORD-CN
  • MA-PWR-CORD-IN
  • MA-PWR-CORD-BR
  • MA-PWR-CORD-TW
  • MA-PWR-CORD-AU
  • MA-PWR-CORD-AR

*1 MA-PWR-CORD-US is included automatically with US orders only

Rack-mount screws are not included in the box, but can be ordered separately. Meraki recommends sourcing rack-mount screws and nuts made for your specific rack. 

Accessories

SFP Modules

The following SFP/Fiber transceivers are supported

SFP Models

  • MS130-8, 8P
  • MS130-24, 24P
  • MS130-48, 48P

Supported Modules

  • MA-SFP-1GB-SX
  • MA-SFP-1GB-LX10
  • MA-SFP-1GB-TX

SFP+ Models

  • MS130-8X
  • MS130-12X
  • MS130-24X
  • MS130-48X

Supported Modules

  • MA-SFP-1GB-SX
  • MA-SFP-1GB-LX10
  • MA-SFP-1GB-TX
  • MA-SFP-10GB-SR
  • MA-SFP-10GB-LR
  • MA-SFP-10GB-ER
  • MA-CBL-TA-1M
  • MA-CBL-TA-3M

* For more information regarding the SFP modules, see the following Cisco Meraki datasheets:

-  SFP and Stacking Accessories 

Troubleshooting

The MS uses LEDs to inform the user of the device's status. Functions are described below, from left to right. For fixed Ethernet ports, the status LED is on the top left or bottom right depending on port orientation. There is also a traffic LED which flashes orange as traffic is sent/received through that port.

Function

LED Status

Meaning

Power

Solid orange

Switch is unable to connect to the Meraki cloud

 

Flashing white

Firmware upgrade in process

 

Solid white

Switch is fully operational and connected to the Meraki cloud

 

Off

Switch does not have power

Switch Ports

Off

Port is operating at less than full speed. For example:

  • 10/100M on a 1GE port
  • 100M/1GE on 2.5GE ports
  • 1G on SFP+ ports
 

Solid green

Port is operating at full speed

  • 1GE on 1GE ports
  • 2.5GE on 2.5GE ports
  • 10GE on SFP+

Common Troubleshooting

My device is connected to the network but not checking in to the Meraki cloud or shows a solid Orange LED.

Confirm that the device is powered on and has a valid IP address that is able to access the Internet. Use the Local Status Page to get more information about the connectivity status of the device such as if it can successfully reach the Local Gateway, Internet, and/or Meraki Cloud servers. If necessary, contact Meraki Support for additional assistance.

 

My Status LED is blinking WHITE 

A blinking WHITE Status LED indicates that the device is in contact with the Dashboard Cloud servers and is performing a firmware update. This can sometimes take 20-45 minutes or more to complete depending on hardware and other factors.

 

My Status LED is blinking ORANGE

The device is not able to successfully communicate with the Dashboard Cloud servers or there may be a hardware issue with the device. Check the Local Status Page of the device to confirm the status and reach out to Meraki Support for further troubleshooting. 

 

Event Log 

The most common Event Log messages and their meaning are listed below.

Port STP change

Indicates the STP state of the port has changed, lists the relevant port number, previous, and new states. Typically accompanied by a 'Port status change' event.

Port status change

Indicates the link state of the port has changed, lists the relevant port number, old, and new state. Always accompanied by a 'Port STP change' event. 

SFP module inserted/removed 

Indicates that an SFP module was either inserted or removed, includes SFP module information for inserted events and always lists the relevant port number. 

 

Licensing

Every MS license is available in 1-, 3-, 5-, 7-, and 10-year terms.

Model

License

Description

MS130-8-HW

MS130-8P-HW

MS130-8X-HW

MS130-12X-HW

LIC-MS130-CMPT-xY

MS130-8 Enterprise license and Support

MS130-8P Enterprise License and Support

MS130-8X Enterprise License and Support

MS130-12X Enterprise License and Support 

MS130-24-HW

MS130-24P-HW

MS130-24X-HW

LIC-MS130-24-xY

MS130-24 Enterprise License and Support

MS130-24P Enterprise License and Support

MS130-24X Enterprise License and Support

MS130-48-HW

MS130-48P-HW

MS130-48X-HW

LIC-MS130-48-xY

MS130-48 Enterprise License and Support

MS130-48P Enterprise License and Support

MS130-48X Enterprise License and Support

MTBF Rating 

 

Model

MTBF at 25°C
(in hours)
MS130-8 1,927,507
MS130-8P 563,569
MS130-8X 1,042,108
MS130-12X 682,400
MS130-24 789,842
MS130-24P 768,152
MS130-24X 677,546
MS130-48 425,296
MS130-48P 309,196
MS130-48X 396,536

 

 

  • Was this article helpful?